Standard stop end

  • Angle blanks and template blanks to be cut to the full gutter profile (height and width)
  • Address the liner to the full stop end height and fold back to the gutter sole
  • Warm the liner material until it becomes pliable, envelope fold the liner to the full height of the original stop end and clamp with the pre-cut template blank
  • Allow the liner material to cool, once cooled trim the excess material across the top of the stop end
  • Remove the clamp and template blank and fix the angle blank with Sharmans specified fixings
  • Up to 450mm across the open top of the gutter (two fixings per end) Up to 900mm across the open top of the gutter (4 fixings per end)
  • Angle blanks should be used where the gutter protrudes past the end of the building
  • If against a wall or underneath cladding a template blank should be used