Format: pdf

 

 

Bespoke moulded side chute (MWSC)
The liner should be pinned and fixed before any hot air welding of the moulded side chute.

Fixings specification engineered for gutter substrate type

Substrate Product Code Pilot hole (if required) Drill speed
STEEL < 3mm HDS-LS-30 N/A 0-2000rpm – Can be full speed
STEEL > 3mm HDS-HS-40 N/A 0-2000rpm – Can be full speed
CONCRETE HDS-CON-45 5mm Diameter 0-950rpm – Typically 750Watt
ASBESTOS HDS-ASB-38 9.5mm Diameter Set to lowest speed

 

When drilling holes into asbestos cement and other highly bonded materials, refer to the current health & safety guide.
The illustration above details an installation with six fasteners – three on each side.
Remember to follow the ‘200 rule’ in order to determine how many fixings are required within pinning regions.

The 200 rule
The maximum gap permitted between fixings in the pinning region is 200mm.
So, for a 300mm gap, an additional fixing is required to bisect at 150mm and a 600mm gap is bridged with two further fixings (one at 200mm and one at 400mm).

Order your bespoke moulded side chute
Designed to discharge water from the side of the gutter, this item is used in many successful Plygene Gutterline installations.
Complete the attached document with your job reference, project dimensions and required quantity to order yours.

 

Function: To discharge water from the side of the gutter

Type: Datasheets