Bespoke moulded side/sump box c/w outlet
Format: pdf

 

Bespoke Moulded Side-Sump Box cw Outlet

Bespoke moulded side sump box c/w outlet (MWOSSB)
The liner should be pinned and fixed before any hot air welding of the side box c/w outlet.

Fixings specification engineered for gutter substrate type

Substrate Product Code Pilot hole (if required) Drill speed
STEEL < 3mm HDS-LS-30 N/A 0-2000rpm – Can be full speed
STEEL > 3mm HDS-HS-40 N/A 0-2000rpm – Can be full speed
CONCRETE HDS-CON-45 5mm Diameter 0-950rpm – Typically 750Watt
ASBESTOS HDS-ASB-38 9.5mm Diameter Set to lowest speed

 

When drilling holes into asbestos cement and other highly bonded materials, the current health & safety guide should be referred to.
The above illustration shows a typical installation including eight fasteners, with four on each side.
To determine how many fixings are required within a pinning region, you should follow the ‘200 rule’.

The 200 rule
The maximum gap permitted between fixings in the pinning region is 200mm.
So, for a 300mm gap between fixings, an additional fixing is required to bisect at 150mm and a 600mm gap is bridged with two further fixings (one at 200mm and one at 400mm).

Order your bespoke moulded side sump box c/w outlet
Designed to increase the capacity of the outlet outside the line of the gutter, this component is an effective part of many Plygene Gutterline installations.
Complete the document attached with your job reference, project dimensions and the quantity you require to order yours.

 

Function: To increase the capacity of the outlet outside the line of the gutter

Type: Datasheets