Bespoke moulded step
Format: pdf
Bespoke moulded step (MWST)
The liner of the step should be pinned and fixed before hot air welding.
Fixings specification engineered for gutter substrate type
Substrate | Product Code | Pilot hole (if required) | Drill speed |
STEEL < 3mm | HDS-LS-30 | N/A | 0-2000rpm – Can be full speed |
STEEL > 3mm | HDS-HS-40 | N/A | 0-2000rpm – Can be full speed |
CONCRETE | HDS-CON-45 | 5mm Diameter | 0-950rpm – Typically 750Watt |
ASBESTOS | HDS-ASB-38 | 9.5mm Diameter | Set to lowest speed |
Remember to refer to the current health & safety guide when drilling holes into highly bonded materials such as asbestos cement.
The illustration above shows a typical installation including eight fasteners but in order to determine exactly how many are required, refer to the ‘200 rule’.
The 200 rule
The maximum permitted gap between fixings in the pinning region is 200mm.
So, a 600mm gap must be bridged with two further fixings (at 200mm and 400mm) and a 300mm gap between fixings requires an additional one to bisect at 150mm.
Order your bespoke moulded step
Designed to enable a step down from one gutter to another, this component is a vital element of several Plygene Gutterline installations. Complete the attached document with your job reference, dimensions and required quantity to order yours.
Function: Step down from one gutter to another
Type: Datasheets