Bespoke moulded back to back stop end
Format: pdf

 

Bespoke Moulded Back-to-Back-Stop-End

 

Bespoke moulded back-to-back stop end (MWUFS)
Before any hot air welding of the back-to-back stop end, the liner should be pinned and fixed.

Fixings specification engineered for gutter substrate type

Substrate Product Code Pilot hole (if required) Drill speed
STEEL < 3mm HDS-LS-30 N/A 0-2000rpm – Can be full speed
STEEL > 3mm HDS-HS-40 N/A 0-2000rpm – Can be full speed
CONCRETE HDS-CON-45 5mm Diameter 0-950rpm – Typically 750Watt
ASBESTOS HDS-ASB-38 9.5mm Diameter Set to lowest speed

 

The current health & safety guide should be referred to when drilling holes into highly bonded materials such as asbestos cement.
The above illustration shows a typical installation including eight fasteners, with four on each side.
Remember to follow the ‘200 rule’ to determine how many fixings are required within pinning regions.

The 200 rule
In the pinning region, the maximum gap permitted between fixings is 200mm.
So, for a 300mm gap between fixings, an additional fixing is required to bisect at 150mm and a 600mm gap is bridged with two further fixings (one at 200mm and one at 400mm).

Order your bespoke moulded back-to-back stop end
Designed to cover expansion joints effectively, this item is an important element on many Plygene gutterline installations.
Flanges are typically manufactured to factory standard sizes but other sizes are available on request.
Complete the attached document with your required quantity, job reference and project dimensions to order yours.

 

Function: To cover an expansion joint

Type: Datasheets